- Home /
- Fire Safety Products /
- Fire Hydrant Accessories
Fire Hydrant Accessories
Savemax India manufactures and supplies a complete range of fire hydrant accessories – including landing valves, RRL hoses, first aid hose reels, hose boxes, two-way and four-way inlets, ISI marked sprinklers, flexible drops, and shaft doors – engineered for installation in fire hydrant systems across buildings, industrial facilities, and infrastructure projects.
50+
Years Legacy
10,000+
Projects Served
100%
In-house Made
Savemax Stainless Steel Double Head Landing Valve
Savemax First Aid Hose Reel Malaysian Type
Savemax Fire Hydrant Accessories: Complete Component Range
Savemax manufactures 18 fire hydrant system accessories across 7 component categories - covering every key element of a standard wet riser or downcomer hydrant system as specified under NBC (National Building Code of India), IS 3844, and TAC guidelines.
Landing valves are the primary water outlet points in a fire hydrant system, installed on every floor of a building to allow fire hose connection during an emergency. Savemax manufactures landing valves in Stainless Steel (SS) body – offering superior corrosion resistance over conventional gunmetal or cast iron alternatives – in both single head and double head configurations.
- Savemax Stainless Steel Single Head Landing Valve – Single outlet, standard specification for most wet riser systems. Installed at each floor landing point with a 63mm outlet for hose coupling connection.
- Savemax Stainless Steel Double Head Landing Valve – Dual outlet configuration, used at floor landings where two hose lines may be required simultaneously – typically specified for high-risk occupancies, large floor plates, or basement installations.
| Material | Stainless Steel body |
| Standard | IS 5290 (Landing Valves for Fire Fighting) |
| Ideal For | Wet riser systems, downcomer systems, multi-storey buildings, hospitals, malls, industrial facilities |
| Certifications | BIS/ISI Marked | CPWD Approved | Euro Certified |
A shot branch pipe (also called a branch pipe or jet/spray nozzle) is the terminal fitting attached to the end of a fire hose, controlling the discharge pattern and flow rate of water during firefighting. Savemax manufactures the shot branch pipe in Stainless Steel – providing the durability, pressure resistance, and corrosion immunity required for emergency use.
- Savemax Stainless Steel Shot Branch Pipe – Compatible with standard 63mm RRL hose couplings. Provides controlled jet or spray discharge for direct fire attack or cooling.
| Material | Stainless Steel |
| Ideal For | Wet riser hose cabinets, fire brigade use, hydrant outlet connection |
| Certifications | BIS/ISI Marked | CPWD Approved |
RRL (Rubberised Reinforced Lined) hose is the standard fire hose used in wet riser hydrant systems across India, specified under IS 636. Savemax supplies RRL Type-A hose pre-fitted with Stainless Steel instantaneous couplings – ready for direct installation into hose boxes and hose cabinets without additional fittings.
- Savemax RRL Hose 15m Type-A with SS Coupling – Standard 15-metre length for floor-level hose box installations in buildings. Covers a suppression radius appropriate for standard floor plates up to 500 sq. mt.
- Savemax RRL Hose 30m Type-A with SS Coupling – Extended 30-metre length for large floor areas, basements, open yards, and industrial sheds where the hydrant outlet-to-fire distance exceeds 15 metres.
| Type | RRL Type-A |
| Diameter | 63mm |
| Coupling | Stainless Steel Instantaneous |
| Standard | IS 636 (Fire Hose – Unlined and Lined) |
| Ideal For | Hose boxes, wet riser systems, fire brigade hydrant connections, industrial hydrant points |
| Certifications | BIS/ISI Marked | CPWD Approved |
A first aid hose reel is a permanently installed, semi-rigid hose system connected directly to the building’s water supply – designed for immediate, untrained use by building occupants before the fire brigade arrives. Unlike RRL hoses that require coupling and deployment, a hose reel is always connected, always pressurised (or pressure-on-demand), and can be operated by a single person in seconds.
Savemax manufactures two variants of first aid hose reel to serve different project specifications:
- Savemax First Aid Hose Reel – Malaysian Type – A swinging-arm reel configuration widely specified in commercial buildings, malls, and hospitality projects. The Malaysian-type reel allows the hose to be pulled out in any direction through 180°, making it accessible from the widest possible area coverage.
- Savemax ISI Type First Aid Hose Reel – The BIS/IS-specification hose reel conforming to IS 884 for installation in buildings as per NBC requirements. Mandatory in most government and CPWD-specified projects.
| Hose Type | 25mm semi-rigid hose |
| Reel Capacity | Typically 30m |
| Standard | IS 884 (First Aid Hose Reel for Fire Fighting) |
| Ideal For | Commercial buildings, offices, hospitals, hotels, residential complexes, malls |
| Certifications | BIS/ISI Marked | CPWD Approved | Euro Certified |
Two-way and four-way inlets (also called Fire Brigade Inlets or Siamese Connections) are external connection points installed on the facade or boundary wall of a building – allowing the fire brigade to pump water directly into the building’s internal wet riser or sprinkler system from their tanker when the building’s internal water supply is insufficient or unavailable.
- Savemax Two Way Inlet – Two inlet connections feeding into a single internal riser outlet. Standard specification for smaller buildings, residential towers, and commercial blocks where one riser serves the building.
- Savemax Four Way Inlet – Four inlet connections feeding into a single or dual riser outlet. Specified for large buildings, hospitals, malls, and industrial complexes with high-demand hydrant systems where the fire brigade may need to pump simultaneously from multiple tankers.
| Standard | IS 904 (Suction Hose Couplings for Fire Brigade Use) |
| Ideal For | External facade of buildings – allows fire brigade tanker connection to internal hydrant riser |
| Certifications | BIS/ISI Marked | CPWD Approved |
Sprinklers are the individual heat-activated discharge heads of an automatic sprinkler system – the most widely mandated fixed fire suppression system in Indian buildings under NBC and local fire NOC regulations. Savemax supplies ISI Marked sprinklers in all three standard orientations:
- Pendant Sprinkler – Installed facing downward from the ceiling. The most common type for standard false-ceiling and open-ceiling installations.
- Upright Sprinkler – Installed facing upward, typically in areas without false ceilings – warehouses, industrial sheds, cold storage, and open plant areas.
- Sidewall Sprinkler – Installed on walls rather than ceilings, projecting water in a quarter-spherical pattern. Specified for narrow corridors, hotel rooms, stairwells, and spaces where ceiling installation is not feasible.
| Standard | IS 15105 (Automatic Sprinkler Systems) |
| Activation | Rated fusible bulb (68°C standard, other temperatures available) |
| Ideal For | Offices, hotels, hospitals, malls, warehouses, residential buildings – anywhere automatic sprinkler systems are installed |
| Certifications | BIS/ISI Marked |
A flexible drop is a flexible hose connector used in suspended ceiling environments to connect the rigid sprinkler branch pipe (above the false ceiling) to the sprinkler head (below the false ceiling) – accommodating building movement, ceiling deflection, and installation misalignment without rigid pipe stress.
- Savemax Flexible Drop – Available in five standard lengths: 700mm, 1000mm, 1200mm, 1500mm, and 1800mm. Allows precise positioning of the sprinkler head below the false ceiling line without cutting or re-routing rigid piping.
| Available Lengths | 700mm | 1000mm | 1200mm | 1500mm | 1800mm |
| Ideal For | False ceiling environments in offices, hotels, hospitals, malls, and residential buildings with suspended ceiling sprinkler systems |
| Certifications | BIS/ISI Marked |
A hose box (also called a hose cabinet or hose reel cabinet) is the enclosure installed on each floor of a building to house the fire hose, branch pipe, and landing valve accessories – keeping them protected, accessible, and compliant with fire NOC requirements. Savemax manufactures hose boxes in MS (Mild Steel) and Stainless Steel body, in single door and double door configurations, across two gauge thicknesses – giving specifiers and procurement teams the widest choice from a single manufacturer.
- Savemax Single Door Hose Box – 18 SWG (MS) – Standard-gauge mild steel single door hose box. Cost-effective option for general commercial and industrial installations.
- Savemax Single Door Hose Box – 16 SWG (MS) – Heavy-gauge mild steel single door hose box. Specified where higher physical durability is required – basements, parking areas, industrial floors.
- Savemax Double Door Hose Box – 18 SWG (MS) – Standard-gauge mild steel double door configuration, housing both a landing valve assembly and a hose reel or RRL hose within a single cabinet.
- Savemax Double Door Hose Box – 16 SWG (MS) – Heavy-gauge mild steel double door hose box for demanding installation environments.
- Savemax Single Door Hose Box – Stainless Steel – Premium SS body single door hose box for installations requiring corrosion resistance – coastal buildings, food processing plants, pharmaceutical facilities, high-specification hospitality projects.
- Savemax Double Door Hose Box – Stainless Steel – Premium SS body double door hose box – the highest specification hose cabinet in the Savemax range.
| Body Options | MS (18 SWG & 16 SWG) | Stainless Steel |
| Door Configuration | Single Door | Double Door |
| Standard | Compatible with NBC and TAC specifications for hose cabinet enclosures |
| Ideal For | Wet riser systems in all building types – commercial, industrial, residential, hospitality, healthcare, infrastructure |
| Certifications | BIS/ISI Marked | CPWD Approved | Euro Certified |
A shaft door is a fire-rated access door installed on the wet riser shaft – the vertical enclosure housing the main riser pipe and valve assembly – at each floor level. It provides maintenance access to the riser infrastructure while maintaining the fire compartmentation integrity of the shaft enclosure.
- Savemax Shaft Door – Manufactured to standard fire shaft dimensions, providing clean access panel integration with the building’s hydrant riser shaft at each floor.
| Ideal For | Wet riser shafts in multi-storey buildings, hospitals, hotels, commercial towers |
| Certifications | BIS/ISI Marked | CPWD Approved |
Understanding the Fire Hydrant System - Where Each Accessory Fits
Buyers sourcing fire hydrant accessories are almost always doing so in the context of a complete hydrant system - either a new installation, a system upgrade, or AMC-based component replacement. Understanding where each Savemax accessory fits within the overall system helps procurement teams and project engineers specify the correct components without gaps.
- Two Way Inlet / Four Way Inlet – fire brigade connection point
Vertical Riser Shaft
- Shaft Door – maintenance access at each floor level
Floor Landing Point (Each Floor)
- Single Head or Double Head Landing Valve – water outlet
- RRL Hose 15m or 30m with SS Coupling – hose for fire attack
- Shot Branch Pipe – nozzle at hose end
- Single Door or Double Door Hose Box (MS or SS) – enclosure for all of the above
First Aid Response Points (Within Floor)
- First Aid Hose Reel (Malaysian Type or ISI Type) – always-ready occupant-use hose
Ceiling / Overhead (Automatic Sprinkler Zone)
- ISI Marked Sprinklers (Pendant / Upright / Sidewall) – automatic activation heads
- Flexible Drop (700mm–1800mm) – riser-to-sprinkler connection below false ceiling
Savemax manufactures and supplies all of these components – allowing a single source procurement for the complete fire hydrant accessories scope on any project.
Certifications & Compliance - Savemax Hydrant Accessories
All Savemax fire hydrant accessories are manufactured and supplied in compliance with the following Indian and international standards:
This certification set makes Savemax hydrant accessories eligible for specification and supply in government tenders, CPWD projects, private developer contracts, and internationally specified EPC and infrastructure projects across India.
Industries & Project Types - Fire Hydrant Accessories Supply
Savemax fire hydrant accessories are specified and supplied across a wide range of building types and project categories:

Commercial Real Estate
Office buildings, IT parks, business centres, retail complexes

Residential
High-rise towers, gated communities, housing societies, affordable housing projects

Healthcare
Hospitals, medical colleges, diagnostic centres, pharmaceutical manufacturing

Hospitality
Hotels, resorts, service apartments, convention centres

Industrial
Factories, warehouses, logistics parks, cold storage facilities

Infrastructure
Metro stations, airports, railway terminals, expressway toll plazas

Government & PSU
Central government offices, defence establishments, PSU campuses, CPWD projects

Education
University campuses, schools, technical institutes, hostels

Data Centres
IT infrastructure buildings with combined wet riser and sprinkler systems
Frequently Asked Questions - Fire Hydrant Accessories
What is included in fire hydrant system accessories?
Fire hydrant system accessories include all the components required to complete a functional wet riser or down comer hydrant system in a building. This covers landing valves (single and double head), RRL fire hoses with couplings, shot branch pipes, first aid hose reels, two-way and four-way inlets for fire brigade connection, hose boxes (cabinets), automatic sprinkler heads, flexible drops for false ceiling sprinkler connection, and shaft doors for riser maintenance access. Savemax manufactures all of these components.
What is the difference between a Single Head and Double Head Landing Valve?
A Single Head Landing Valve has one outlet connection – suitable for floor landings where one hose line is sufficient for the fire risk and floor area. A Double Head Landing Valve has two outlet connections on a single body – specified where two hose lines may need to be operated simultaneously, typically in large floor areas, basements, high-risk industrial spaces, or buildings with high occupancy.
What is the difference between a Malaysian Type and ISI Type hose reel?
The Malaysian Type hose reel features a swinging arm design that allows the hose to be drawn out in any direction within a 180° arc – offering wider area coverage from a single point. The ISI Type hose reel is the BIS-standard (IS 884) configuration mandatory for CPWD and government building specifications. Both serve as first aid firefighting equipment for building occupants. Your fire safety consultant or fire NOC requirement will specify which type is applicable.
What is a flexible drop in a sprinkler system?
A water mist fire extinguishing system works by breaking water into ultra-fine droplets of 50–150 microns in size. These microscopic particles have a dramatically larger surface area than bulk water, allowing near-complete vaporisation within the fire environment. This rapid evaporation absorbs enormous amounts of heat, displaces oxygen through steam expansion, and creates a thermal radiation barrier — all simultaneously. When combined with compressed air foam (as in Savemax’s CAFS Water Mist range), the system also creates a surface-blanketing foam for fuel suppression.
What gauge of hose box should I specify - 16 SWG or 18 SWG?
A flexible drop is a short flexible hose connector used to bridge the connection between the rigid sprinkler branch pipe (installed above the false ceiling) and the sprinkler head (positioned below the false ceiling level). It allows the sprinkler head to be precisely positioned without requiring the rigid branch pipe to be cut or re-routed to exact ceiling heights. Savemax supplies flexible drops in five lengths – 700mm, 1000mm, 1200mm, 1500mm, and 1800mm.
Can I source all hydrant accessories for a complete project from Savemax?
Yes. Savemax manufactures all 18 fire hydrant system accessories in-house – including landing valves, RRL hoses, shot branch pipes, first aid hose reels, inlets, sprinklers, flexible drops, hose boxes, and shaft doors. A single enquiry to our project team will yield a component-wise quotation covering your complete hydrant accessories scope, with certifications and datasheets included.
Ensure Complete Fire Safety Today
Talk to our fire safety experts for site assessment, product recommendations, and project-based procurement quotations within 24 hours.
CALL SALES
+91 95999 28408
+91 96500 12289
EMAIL US
info@savemaxindia.com
Quote within 24 hours




